Acura® electro        Acura® manual        Acurex TM        Calibra®
 
CalibrexTM           DosysTM        ProfillerTM          Qualitips®        StepperTM
HOME
CONTACT
SITE MAP
EN DE FR IT ES PT
CN JP TW RU
LABORATORY DIVISION

 
 

  PRODUCTS >

Laboratory syringes > DosysTM 160 series


DosysTM 164 premium
Self-refilling, automatic syringe with detachable, Luer Lock valve system. Enhanced corrosion resistance thanks to carefully selected materials. Volumes ranging 0.1 to 10 mL. Package includes syringe and 1 meter silicone feed tube, sinker, PVC protection sleeve, aspiration, vent and dosing cannulas, set of spare for valve, operating instructions.

DosysTM 163 classic
Self-refilling, automatic syringe with integrated, Luer Lock valve system. Volumes ranging 0.025 to 2 mL. Ideal for aquous, non corrosive liquids. Package includes syringe and 1 meter silicone feed tube, sinker, PVC protection sleeve, aspiration and vent cannulas, set of spare for valve, operating instructions.

DosysTM 162 basic
Automatic syringe without valve system. Luer Lock nozzle. Volumes ranging 0.1 to 5 mL. Package includes syringe, PVC protection sleeve and operating instructions.

 

Ordering and performance information
Dosys premium 164 Imprecision (CV %)
Cat. No. Vol. mL Div. mL Min. vol. Mid. vol. Max. vol.
164.0501 0.1 - 1 0.05 < 0.7% < 0.6% < 0.4%
164.0502 0.3 - 2 0.1 < 0.6% < 0.5% < 0.4%
164.0505 0.5 - 5 0.5 < 0.5% < 0.4% < 0.2%
164.0510 1 - 10 1 < 0.5% < 0.4% < 0.2%

Dosys classic 163 Imprecision (CV %)
Cat. No. Vol. mL Div. mL Min. vol. Mid. vol. Max. vol.
163.05003 0.025 - 0.3 0.025 < 1.8%1) < 1.2% < 0.5%
163.05005 0.1 - 0.5 0.1 < 1.2% < 0.9% < 0.4%
163.0501 0.1 - 1 0.05 < 0.7% < 0.6% < 0.4%
163.0502 0.3 - 2 0.1 < 0.6% < 0.5% < 0.4%
163.0505 0.5 - 5 0.5 < 0.5% < 0.4% < 0.2%
163.0510 1 - 10 1 < 0.5% < 0.4% < 0.2%
1) Measured at 0.075 mL

Dosys basic 162 Imprecision (CV %)
Cat. No. Vol. mL Div. mL Min. vol. Mid. vol. Max. vol.
162.0501 0.1 - 1 0.05 < 0.7% < 0.6% < 0.4%
162.0502 0.3 - 2 0.1 < 0.6% < 0.5% < 0.4%
162.0505 0.5 - 5 0.5 < 0.5% < 0.4% < 0.2%
Performance values obtained with bi-dist. water at constant temperature
(± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.

Models
Two ring syringes
Pistol grip syringes
All-glass syringes
 
Highlights
Optimal hand balance
Fast volume setting
Plunger tightness without O-ring
Chemically resistant materials
Few parts to disassemble
Autoclavable
 
Accessories
Injection needles
Multiple dispensing manifold
Enhanced tightness set
Syringe stand
Barrel brushes
Drenchers
Tips and straws
Aspiration valve unit
 
Spares
Glass barrels
Spare bags
Cannulas
Feed tubing
 
Application
Dispensing / distribution
Sterile work
Filtration
Dosy by dose
Aspiration
Animal injection
 
Documents
Leaflet 150-160-170
Operating instructions
 
Products and specifications are subject to change without prior notice.