Laboratory Division
Socorex Programme ISO

Programme (ISO 8655 / 17025)

Service and calibration levels should fulfill all requirements from any research or routine laboratory. If none of the existing levels is adequate, contact us for custom solutions.

Choice of Service Levels

Volume control 3x5 measurements "as found", procedure includes:

  • Disinfection
  • Instrument registration
  • Gravimetric verification based on ISO 8655 using manufacturer’s tolerances, 5x measurements on min, mid. and max. volumes 
  • QC certificate “as found”

Calibration 2x4 measurements "as left", procedure includes:

  • Disinfection
  • Instrument registration
  • Visual control
  • Disassembling, cleaning
  • Tightness part replacement as needed
  • Other faulty part replacement as needed
  • Function and tightness check under pressure
  • Gravimetric calibration based on ISO 8655 using manufacturer’s tolerances, 4x measurements on min. and max. volumes
  • QC certificate “as left”

Calibration 2x10 measurements "as left", procedure includes:

  • Disinfection
  • Instrument registration
  • Visual control
  • Disassembling, cleaning
  • Tightness part replacement as needed
  • Other faulty part replacement as needed
  • Function and tightness check under pressure
  • Gravimetric calibration based on ISO 8655 using manufacturer’s tolerances, 10x measurements on min. and max. volumes
  • QC certificate “as left”

Calibration 2x10 measurements "as left", procedure includes: 

  • Disinfection
  • Instrument registration
  • Visual control
  • Disassembling, cleaning
  • Tightness part replacement as needed
  • Other faulty part replacement as needed
  • Function and tightness check under pressure
  • Calibration according to ISO 17025 - 10x measurements on min. and max. volumes
  • ISO 17025 accredited certificate

Calibration 3x10 measurements "as left", procedure includes:

  • Disinfection
  • Instrument registration
  • Visual control
  • Disassembling, cleaning
  • Tightness part replacement as needed
  • Other faulty part replacement as needed
  • Function and tightness check under pressure
  • Gravimetric calibration based on ISO 8655 using manufacturer’s tolerances, 10x measurements on min., mid. and max. volumes
  • QC certificate “as left”

Calibration 3x10 measurements "as left", procedure includes:

  • Disinfection
  • Instrument registration
  • Visual control
  • Disassembling, cleaning
  • Tightness part replacement as needed
  • Other faulty part replacement as needed
  • Function and tightness check under pressure
  • Calibration according to ISO 17025 - 10x measurements on min., mid. and max. volumes
  • ISO 17025 accredited certificate

Calibration 4x10 measurements "as found" and "as left", procedure includes:

  • Disinfection
  • Instrument registration
  • Gravimetric verification based on ISO 8655 using manufacturer tolerances, 10x measurements on min. and max. volumes
  • QC certificate “as found”
  • Visual control
  • Disassembling, cleaning
  • Tightness part replacement as needed
  • Other faulty part replacement as needed
  • Function and tightness check under pressure
  • Gravimetric calibration based on ISO 8655 using manufacturer’s tolerances, 10x measurements on min. and max. volumes
  • QC certificate “as left”

Calibration 6x10 measurements "as found" and "as left", procedure includes:

  • Disinfection
  • Instrument registration
  • Gravimetric verification based on ISO 8655 using manufacturer tolerances, 10x measurements on min. mid. and max. volumes
  • QC certificate “as found”
  • Visual control
  • Disassembling, cleaning
  • Tightness part replacement as needed
  • Other faulty part replacement as needed
  • Function and tightness check under pressure
  • Gravimetric calibration based on ISO 8655 using manufacturer’s tolerances, 10x measurements on min., mid. and max. volumes
  • QC certificate “as left”

Calibration 6x10 measurements "as found" and "as left", procedure includes:

  • Disinfection
  • Instrument registration
  • Gravimetric verification based on ISO 8655 using manufacturer tolerances, 10x measurements on min, mid, and max. volumes
  • QC certificate “as found”
  • Visual control
  • Disassembling, cleaning
  • Tightness part replacement as needed
  • Other faulty part replacement as needed
  • Function and tightness check under pressure
  • Verification and calibration according to ISO 17025 - 10x measurements on min., mid. and max. volumes
  • ISO 17025 accredited certificate "as found" and "as left"
  •  Choice of services and tests done at client’s laboratories (Switzerland)
  • Balances, measuring equipment, hard / software.
  • Quotation upon request 
  • Old / damaged liquid handling instruments have a residual value
  • Send your old instruments, whatever the brand and condition
  • Attractive discount when purchasing equivalent Socorex models
  • Contact Socorex Service Center or your local distributor for details.

 

pdfSocorex Service Center Instrumentenaustausch

pdfSocorex Service Center Echange d'instruments

  • Calibration according to ISO 17025 - 10x measurements on min., mid. and max. volumes
  • ISO 17025 accredited certificate "as left"

Service Comparison

https://www.socorex.com/images/stories/SC_programme_table_EN.svg

Benefit from our long term experience.

Knowledge base

Get access to documents and videos.

Read more

Contact us

Send us your questions and remarks.

Read more